1. The Hidden Cost
A ship's seawater intake is a chain: grating → sea chest → strainer → pump → piping → heat exchangers, box coolers, HVAC. Biofouling only needs to settle in a few low-flow spots along that chain to cause trouble — and the first sign is rarely visible growth. It's a rising cooling-water temperature differential or a strainer needing more frequent cleaning.
A published cost study on an 8,000 BHP vessel found biofouling in the engine cooling system alone could cost over US$60,000/month in lost performance — before any hull damage is visible. Cleaning after the fact adds risk too: industry guidance warns that dislodged fouling debris can travel downstream and clog pumps, valves and coolers.

2. What It Does
MGPS (Marine Growth Prevention System, also called ICAF) uses a copper anode paired with an aluminium or iron anode, mounted in the sea chest or strainer and fed a small, controlled DC current. The copper anode releases trace copper ions — on the order of a few parts per billion — into the incoming seawater, a concentration low enough to stay well below any harmful level but sufficient to stop larvae and algae spores from settling on pipe walls.
Seawater flow then carries those ions through the rest of the internal circuit — piping, heat exchangers, box coolers, condensers — so protection isn't limited to the sea chest itself. The paired aluminium or iron anode runs alongside it, helping limit corrosion on the same wetted surfaces. It's a continuous, low-power process rather than a periodic treatment. Cathelco (Evac), one of the major MGPS suppliers, reports its systems installed on over 50,000 vessels worldwide.

3. MGPS Anode ≠ ICCP Anode
Same word "anode," same use of controlled current — different job, different place.
|
|
MGPS Anode |
ICCP Anode |
|
Location |
Inside sea chest /
piping |
Outside, on the hull |
|
Protects |
Internal piping
& heat exchangers |
Hull plating |
|
Function |
Releases ions to
stop fouling & corrosion |
Current stops hull
corrosion |
|
Material |
Copper +
aluminium/iron alloy |
Titanium (MMO/platinum
coated) |
|
Service life |
Anode consumed,
scheduled replacement |
Often 5–15+ years
before replacement |
Per MGPS procurement guidance: "MGPS/ICAF anodes... are not ordinary sacrificial cathodic-protection anodes" — and ICCP is a separate hull-corrosion technology. The two coexist on most vessels but are never interchangeable: one protects the hull, the other protects the piping. Confirm with your supplier which function you actually need before ordering.
4. What You Gain
Keeping piping and heat-exchanger surfaces free of growth avoids the kind of performance drift documented in the case above, where unchecked biofouling in an engine cooling system ran into tens of thousands of dollars a month. It also means less reactive maintenance — fewer emergency strainer clear-outs and pipework descaling jobs, and less risk of dislodged debris clogging downstream equipment during cleaning.
Because the same seawater circuit commonly feeds both engine cooling and fire pumps, keeping it clear supports fire-system reliability as well, not just cooling performance. The system runs on controlled electrolysis rather than chemical dosing, which is one reason MGPS installations are widely approved by classification societies. And because anode consumption is predictable, replacement becomes a scheduled, budgeted cost rather than an emergency one.
As a source manufacturer, KIG supplies directly to distributors, contractors and end-users worldwide, supporting customized designs (weight, dimensions, alloy grade, packaging) with test reports available for tender qualification. Products and technical support are provided for both domestic and international engineering projects.
For technical datasheets or project-specific recommendations, engineering and procurement teams are welcome to contact Xi an KIG Technology Co., Ltd directly.