Installation & Handling of Marine Ag/AgCl Reference Electrode Installation Guidelines

Proper installation is essential to ensure accurate potential measurement and long-term performance of the Ag/AgCl reference electrode.

  • Install the electrode in direct contact with seawater, close to the structure being monitored.
  • Position the electrode so that it represents the true local potential of the structure.
  • Secure the electrode using appropriate clamps, brackets, or mounting hardware to prevent movement.
  • Ensure the sensing surface remains exposed to seawater and is not blocked by coatings or debris.

Cable & Connection Requirements

  • Protect lead cables from mechanical damage, abrasion, and sharp edges.
  • Route cables securely to avoid tension, bending, or chafing.
  • For permanent installations, all cable joints and terminations must be waterproofed to prevent seawater ingress and signal instability.

Maintenance & Inspection

  • Ag/AgCl reference electrodes generally require minimal maintenance.
  • Periodically inspect cable insulation and connection integrity, especially in harsh offshore environments.
  • Monitor potential readings; replace the electrode if abnormal drift or physical damage is detected.
  • Portable electrodes should be stored in a moist environment when not in use to maintain electrode stability (if applicable).

Safety & Compliance

  • Installation should be carried out by qualified personnel familiar with cathodic protection systems.
  • Ensure cable routing does not create safety hazards on decks or subsea structures.
  • Follow applicable marine electrical safety standards and cathodic protection guidelines.
  • Confirm depth and pressure ratings for deep-water or high-pressure installations.

Ordering & Customization

When ordering a Marine Ag/AgCl Reference Electrode, please specify:

  • Required cable length
  • Operating temperature range
  • Installation environment (subsea, splash zone, permanently submerged)
  • Any certification or project-specific requirements

Custom configurations are available to meet specific project and installation needs.