Product Overview
Marine Ag/AgCl Reference Electrode is designed for long-term corrosion
potential monitoring and cathodic protection (CP) systems in marine and
offshore environments. It provides a stable and reliable reference potential in
high-chloride conditions such as seawater, making it the preferred reference
electrode for submerged and offshore applications.
Ag/AgCl reference electrodes are widely used in offshore platforms, subsea
pipelines, ship hulls, and coastal metal structures where accurate CP potential
measurement is critical for asset integrity and corrosion control.
Operating Principle
The electrode operates based on the reversible electrochemical equilibrium
between metallic silver (Ag) and silver chloride (AgCl) in a
chloride-containing electrolyte.
This equilibrium produces a stable and reproducible reference potential
relative to seawater, ensuring accurate and repeatable potential measurements
for cathodic protection assessment.
Typical Applications
- Marine and subsea
pipelines
- Offshore platforms and
risers
- Ship hull corrosion
monitoring
- Submerged and coastal
steel structures
- Cathodic protection
surveys and system verification
Key Features
- Stable reference
potential in high-chloride seawater environments
- High-purity silver with
durable AgCl coating for long service life
- Low potential drift and
minimal polarization
- Robust construction for
permanent or portable use
- Suitable for continuous
long-term marine deployment
Technical Specifications (Typical)
|
Parameter |
Typical Value |
|
Electrode Type |
Ag/AgCl (Silver/Silver Chloride) |
|
Reference Potential Accuracy |
±5 mV after stabilization |
|
Potential Stability |
±1 mV over 24 hours |
|
Operating Temperature |
–5 °C to +90 °C |
|
Electrode Material |
High-purity silver & AgCl |
|
Construction |
Seawater-compatible housing |
|
Cable Length |
Standard or customized |
|
Design Service Life |
≥ 30 years (in seawater) |
|
Insulation Resistance |
> 1 MΩ (typical) |
|
Environmental Use |
Fully submerged seawater |
|
Temperature Coefficient |
~ –0.65 mV/°C |

Note: Specifications may vary
depending on model and application.